🚚 Item will be delivered on or before
| Range | EasyLogic |
|---|---|
| Device short name | PM1125H |
| Product or component type | Power meter |
| Power quality analysis | total harmonic distortion |
|---|---|
| Device application | Energy monitoring |
| Type of measurement | Current Voltage Frequency Power factor per phase Power factor average Power Energy Active power demand Reactive power demand Apparent power demand Phase unbalance Phase angle RPM |
| Metering type | Phase currents Average current Iavg Calculated neutral current Voltage U21, U32, U13, V1, V2, V3 Average voltage Vavg Active power P, P1, P2, P3 Apparent power S, S1, S2, S3 Reactive power Q, Q1, Q2, Q3 Active, reactive, apparent energy (signed, four quadrant) Demand power P, Q, S Unbalance current Unbalance voltage |
| Counter functions | ON hour counting ON-load hour counting Power interruption |
| [Us] rated supply voltage | 48...277 V AC 45...65 Hz 48...277 V DC |
| Network frequency | 50 Hz 60 Hz |
| [In] rated current | 1 A 5 A |
| type of network | 3P 2P + N 1P + N 3P + N 2P |
| Maximum power consumption in VA | 4 VA at 240 V between phase and neutral |
| Maximum power consumption in W | 2 W at 240 V |
| Display type | 8 segments LED |
| Display colour | Red |
| Messages display capacity | 3 fields of 4 characters |
| Display digits | 12 digit(s) - 14.2 mm in height |
| Communication of data | Reading of measurements |
| Tamperproof of settings | Protected by access code |
| Sampling rate | 32 samples/cycle |
| Measurement current | 5…6000 mA |
| Signal | Voltage (impedance 5 MOhm)4 x Current 0.005...10 A (impedance 0.3 MOhm)6 x |
| Measurement voltage | 46…277 V AC 50...60 Hz between phase and neutral 80…480 V AC 50...60 Hz between phases 100…999000 V AC 50...60 Hz with external VT |
| Frequency measurement range | 45…65 Hz |
| Measurement accuracy | Current +/- 0.5 % Voltage +/- 0.5 % Frequency +/- 0.05 % Power factor +/- 0.01 Reactive power +/- 2 % Active power +/- 0.5 % Apparent power +/- 0.5 % Active energy +/- 0.5 % Reactive energy +/- 2 % Apparent energy +/- 0.5 % Harmonic distortion (I THD & U THD) +/- 5 % |
| Accuracy class | Class 0.5S active energy conforming to IEC 62053-22 Class 2 reactive energy conforming to IEC 62053-23 |
| Demand intervals | 1 s |
| Local signalling | Green LED: activity Red LED: output signal 1...9999000 pulse/ k_h (kWh, kVAh, kVARh) |
| Communication port protocol | Modbus at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none - 2 wires, insulation 2500 V |
| Communication port support | Screw connector: RS485 |
| mounting mode | Flush-mounted Vertical |
| Mounting support | Framework |
| Type of installation | Indoor installation Must be permanently connected and fixed |
| Measurement category | Category III 480 V |
| Electrical insulation class | Class II Double insulation |
| Connections - terminals | Current circuit: screw clamp terminals (bottom) 2.08…3.31 mm² cable(s) Voltage circuit: screw clamp terminals (top) 0.82…3.31 mm² cable(s) Control circuit: screw clamp terminals (top) 0.82…3.31 mm² cable(s) Communication: screw clamp terminals (bottom) 0.33…3.31 mm² cable(s) |
| Tightening torque | Current circuit: 0.9…1 N.m Philips No 2 screwdriver Voltage circuit: 0.9…1 N.m Philips No 2 screwdriver Control circuit: 0.9…1 N.m Philips No 2 screwdriver Communication: 0.5…0.6 N.m Philips no 1 screwdriver |
| Wire stripping length | Current circuit: 3.68 mm for terminal connection Voltage circuit: 7 mm Control circuit: 7 mm Communication: 6 mm |
| Standards | IEC 61010-1:ed. 3 UL 61010-1:ed. 3 |
| Product certifications | CE conforming to IEC 61010-1 CULus conforming to UL 61010-1 CULus conforming to CSA C22.2 No 61010-1 |
| Width | 96 mm |
| Depth | Outside : 13 mm Panel : 49 mm |
| Height | 96 mm |
| Electromagnetic compatibility | Electrostatic discharge conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 Surge immunity test conforming to IEC 61000-4-5 Conducted RF disturbances conforming to IEC 61000-4-6 Magnetic field at power frequency conforming to IEC 61000-4-8 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 Emission tests conforming to FCC part 15 class A Emission tests conforming to FCC part 15 Subpart C Emission tests conforming to FCC part 15 Subpart E |
|---|---|
| Overvoltage category | III |
| IP degree of protection | IP51 front: conforming to IEC 60529 IP30 body: conforming to IEC 60529 |
| Relative humidity | 5…95 % |
| Pollution degree | 2 |
| Ambient air temperature for operation | -10…60 °C |
| Ambient air temperature for storage | -20…70 °C |
| Operating altitude | <= 2000 m |
| service life | 7 year(s) |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 11.5 cm |
| Package 1 Width | 8.7 cm |
| Package 1 Length | 12 cm |
| Package 1 Weight | 350 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 18 |
| Package 2 Height | 30 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 6.8 kg |
| Pallet layers | 2 |
| Vendor | INDUSWELL |
|---|---|
| Type | Industrial & Scientific |
| Sku | METSEPM1125HCCL05 |
| Weight | 0.3 kg |